This downstream pressure washer injector features an adjustable 1/4-inch hose barb. It is made of brass for durability and corrosion resistance. General Pump engineered downstream injector to handle a flow rate of 3-5 GPM and a maximum pressure of 4500 PSI. It can also be used in car washes.

Prep 65

Prop 65

 
 

Technical Specifications

Max PSI: 4500
Max Temperature: 190 degrees F
Min GPM: 3
Max GPM: 5
Inlet Port: 3/8 inch
Outlet Port: 3/8 inch

Product Description

3-5 GPM Downstream Chemical Injector

General Pump 100825 is a downstream chemical injector for pressure washers and car washes with a 1/4-inch hose barb that is adjustable. It handles a flow rate of 3-5 GPM and a maximum pressure of 4500 PSI. This adjustable downstream injector is made with brass for durability and corrosion resistance.

Specifications:

  • Manufacturer Product Number: 100825
  • Flow Rate: 3.0 to 5.0 GPM
  • Max PSI: 4500
  • Max Temperature: 190°F
  • Inlet Port: 3/8" NPT-M
  • Outlet Port: 3/8" NPT-M
  • Hose Barb: 1/4", adjustable
  • Material: Brass
  • O-Ring: Viton

Application:

  • Car Washes
  • Pressure Washing

Installation:

  • Install valve with direction arrow pointing downstream. For proper operation, a control device such as a dual lance wand, quick couple nozzles, or an adjustable nozzle holder must be used to lower the system pressure at the nozzle. Warning: Under no circumstances should the system pressure exceed the maximum rated pressure of any component.

Troubleshooting:

  • Injector will not draw liquid
    • Cause:
      1. Incorrect nozzle
      2. The system is not in low-pressure mode
      3. Discharge hose is too long 
      4. Chemical line is clogged
    • Solution:
      1. Check and change the nozzle
      2. Change or adjust the nozzle to put the system in low-pressure mode
      3. Reduce the length of the discharge hose or change the injector
      4. Clear chemical line of obstruction
  • Rate of draw seems too slow
    • Cause:
      1. Discharge hose is too long
      2. Air leak in chemical line
      3. Chemical is too viscous
    • Solution:
      1. Reduce the length of the discharge hose or change the injector
      2. Locate and repair the leak
      3. Reduce the chemical with water to decrease viscosity
  • Chemical injector is leaking from hose barb
    • Cause:
      1. Obstruction in hose barb check valve
      2. Damaged O-ring in check valve
    • Solution:
      1. Disassemble and remove obstruction
      2. Remove and replace O-ring
  • Excessive pressure load on pump, motor, or engine
    • Cause
      1. Clogged injector
      2. Improperly sized injector orifice
    • Solution
      1. Clear injector orifice of obstruction
      2. Change orifice

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm (For more information go to www.p65warnings.ca.gov).

Product Reviews

0  Customer Review(s)
5 Star
0  (0%)
4 Star
0  (0%)
3 Star
0  (0%)
2 Star
0  (0%)
1 Star
0  (0%)

CID: -1 QueryString:general-pump-100825-gp-adjustable-brass-downstream-chemical-injector-3-5-gpm| Runtime:falsep-38592.aspx/p-38592.aspxen-US2https://www.highpressurepumpsandparts.com/6/20/2026searchEngineName=general-pump-100825-gp-adjustable-brass-downstream-chemical-injector-3-5-gpmcompunix.productreviews.xml.config102036516949TrueUSDTrue216.73.217.880TrueFalse12:35 AM1FalseUSDTrueen-USFalse0en-US385921FalseFalseproduct| LastCustomerReview:
Updating...
Loading...